123solar
Comandi per 123Solar
Aurora
Link
Autore Curtronics
Download versione 1.9.0
Testare Aurora
aurora -a 2 -k 364 -Y 3 /dev/ttyUSB0 aurora -a 2 -p -n -f -g -m -v -Y3 /dev/ttyUSB0
Manuale
v1.8.7
Uso:
aurora [Opzioni] Device
Opzioni:
-A, --last-alarms Get last four alarms (once displayed FIFO queue is cleared) -b, --verbose Verbose mode. For maximum effectiveness should be the first option on the command line -C, --calc-value=<num[:$]> Calculate monetary value using <num> * kWh. ":$" is optional and if included the character(s) represented by the "$" will be used to denote monetary type in the output. Defaults to "$" -c, --columnize Output data in columns --> for -d, -e, -D, -3, -E, -t, & -T options only will disable any other options -- if value ends with an "*" reporting of that item may not be in inverters firmware -d <num>, --get-dsp=<num> Get DSP data <num> indicates string to get data for. 0 indicates both 1 for only string 1, 2 for only string 2. <num> is required for short option and <num> is optional for long option and if omitted for long option data for both input strings will be retrieved -D, --get-dsp-extended Get more DSP data -3, --get-dsp-3phase Get 3-Phase DSP data -e, --get-energy Get Cumulated Energy readings (Excluding Central) -E <num>, --get-energy-central=<num> Get Cumulated Float Energy readings (Central&TRIO only) <num> days 1 to 366 Default 366 <num> is required for short option and optional for long option -f, --firmware-ver Query for Firmware Version string -g, --mfg-date Query for Inverter Manufacturing Date -h, --help This text -i, --get-count=<bitmask> Display Inverter Time Counters <bitmask> is required for short option is optional for long option and if omitted for long option then all counters will be displayed and Partial counter will be reset 1 = "Total Run Time" 4 = "Grid Connection Time" 2 = "Partial Run Time" 8 = "Reset Partial Run Time" -j, --get-joules Display Energy cumulated in the last 10 seconds -K, --use-kmult=<num> Adjust vaules reported by -k, --daily-kwh by "<num>" multiplier -k <num>, --daily-kwh=<num> Get past daily kWh for <num> days (1-366) <num> is required for short option and optional for long option and if omitted for long option then all 366 days or as many that are found will be displayed -L <num>, --adjust-time=<num> Automatically adjust the inverter time if it differs from the computer time. If <num> is 0 (zero) do a Daylight Savings Time check. If <num> is>= 1 change the inverter time if it differs by <num> or more seconds. See the README for more information and constraints -l <num>, --read-wait=<num> Timeout for the read to the serial port. <num> in 1/10ths seconds. Default is 1 (0.1 sec). See the README file for important information on this option -M <num>, --max-runtime=<num> Maximum amount of time in seconds that aurora will run trying to get data from the inverter -m, --get-conf Query for Inverter System Configuration -n, --serial-number Query for Inverter Serial Number -N <num>, --central=<num> Indicates Aurora Central ** Experimental ** 0 indicates Master, 1 indicates Slave -o, --output-file=<filename> Append data to file (Created if nonexistant) Note: If -c option is used only -d, -e, -D, -3, -E, -t, & -T options will output to file -O, --part-number-central Query for Inverter Part Number (Central only) -p, --part-number Query for Inverter Part Number -P <num>, --comm-pause=<num> Wait <num> us between sending commands to inverter (1-1000000) -Q, --use-qmult Use inverter specific multiplier if known to adjust values reported by -q, --energy-sent -q <num>, --energy-sent=<num> Get past energy delivered to the grid ** Experimental ** in 10 second intervals for <num> minutes (1-1440). <num> is optional for long option and if omitted all data, ~24 hours worth will be reported. It is suggested the -Y option be used with this due to the extensive length of time this could take. See the README file for important information on this option -R <num>, --read-timeout=<num> Serial port read retry timeout value when reading a character from the Inverter (mS - minimum 200) See the README file for important information on this option -r, --calc-grid-power Calc Grid power using Grid Voltage * Grid Current, instead of reporting the Inverter's value. --> for -d option only, ignored when used with -c option (Inverter typically reports a lower value. This affects Inverter conversion efficiency value.) -S, --set-time Set Inverter Date/Time to system time -s, --get-state Get Inverter State -T, --get-loctime Display computer Date/Time -t, --get-invtime Display Inverter Date/Time -V, --version Aurora communications program version -v, --inv-version Query for Version string -U <num>, --read-pause=<num> Pause <num> milli-seconds after sending command to inverter before reading response from inverter (1-10000) -u, --rpt-read-pause Report when/that pausing before read -W, --swap-endian Swap Endianness -w <num>, --lock-wait=<num> Seconds to wait to lock serial port. (1-30) -X, --rts-cts Enable RTS/CTS on the serial port. -x, --xon-xoff Enable XON/XOFF on the serial port. -Y <num>, --retries=<num> Retry failed communications with inverter up to <num> times (1-100) -y, --rpt-retries Report the number of retires done
Parametri obbligatori
-a <num>, --address=<num> Inverter address. 1-31 on older inverters, 1-63 on newer inverters. Device Serial Device.
123solar.txt · Ultima modifica: 2023/09/02 09:40 da 127.0.0.1